Manual topcon 105n




















Display for Safe Use In order to encourage the safe use of products and prevent any danger to the operator and others or damage to properties, important warnings are put on the products and inserted in the instruction manuals. Do not look at the sun through a telescope. Do not cover the charger while it is charging. Do not use damaged power cable, plug and socket. Do not use a wet battery or charger. Never use an instrument near flammable gas, liquid matter, and do not use in a coal mine.

Do not dispose in fire or heat. Do not use any power voltage except the one given on manufacturers instructions. Do not use any other type of charger other than the one specified. Do not use an AC cable incompatible with the power supply voltage in use. Do not short circuit battery when storing it. Do not stand or sit on the carrying cases. Do not use a carrying case with a damaged which belts, grips or latches. Always check that the screws of tripod are tightened.

Young children should be supervised to ensure that they do not play with the appliance. User 1 This product is for professional use only! The user is required to be a qualified surveyor or have a good knowledge of surveying, in order to understand the user and safety instructions, before operating, inspecting or adjusting. Display for Safe Use. Safety Cautions. Exceptions from Responsibility. Standard Set Composition. Setting Instrument Up For Measurement. Setting of the Atmospheric Correction.

Setting Coordinate Values of Occupied Point. Appendix-1 Precaution when Charging or Storing Batteries Standard Set Composition The numerical value in parentheses shows the quantity. GTSN series with lens cap 1. Make sure that all of the above items are with the instrument when purchased. Remarks: Plumb bob set and plumb bob hook are supplied for certain markets. In general, the upper three lines display measured data, and the bottom line displays the soft key function which changes with the measuring mode.

The operating time will become short if a heater is used. Star key mode is used for each presetting or displaying as follows.

Switches menu mode and normal mode. To set application measurements and adjust in the menu mode. Returning to the measurement mode or previous layer mode from the mode set. The functions are according to the displayed message.

Angle measurement mode. Select Off-set measurement mode Select stake out measurement mode Switches meter, feet or feet and inch unit. The function of soft keys is shown on next page P1. Sets a prism height by input values. Sets an instrument height by input values. Sets an instrument coordinate point by input values. The function of soft keys is shown on next page P3.

Select Off-set measurement mode Switches meter, feet or feet and inch unit. The following instrument options can be selected from the H : 1. Adjustment the contrast of the display 0 to 9 steps [ or ] 2. Adjustment the reticle illumination 1 to 9 steps [ or ] 3.

Setting Tilt Correction [F2] 5. Press the up or down arrow keys to adjust the contrast. Press [F1] again to turn the back light OFF. When reflected light from the prism is received, a buzzer sounds. This function is good for easy collimation when the target is difficult to find. Press the [F4] key to view the set audio screen. The details necessary for the connection with the GTSN Series are obtained from its Interface Manual which is optionally available.

Please refer to the manual. Level and center the instrument precisely to insure the best performance. Reference: Leveling and Centering the Instrument 1. Setting up the Tripod First, extend the extension legs to suitable lengths and tighten the screws on their midsections.

Attaching the Instrument on the Tripod Head Place the instrument carefully on the tripod head and slide the instrument by loosening the tripod screw. If the plumb bob is positioned right over the center of the point, slightly tighten the tripod screw. The bubble is now located on a line perpendicular to a line running through the centers of the two leveling screws being adjusted.

Leveling screw C. Centering by Using the Optical Plummet Telescope Adjust the eyepiece of the optical plummet telescope to your eyesight. Slide the instrument by loosening the tripod screw, place the point on the center mark, and then tighten the tripod screw.

Sliding the instrument carefully not to rotate that allows you to get the least dislocation of the bubble. Turn the leveling screw C to bring the bubble to the center of the circular level. Completely Leveling the Instrument Leveling the instrument precisely in a similar way to 4. Rotate the instrument and check to see that the bubble is in the center of the plate level regardless of telescope direction, then tighten the tripod screw hard.

Leveling screw A. Confirm the battery power remaining display. Contrast adjustment You can confirm prism constant value PSM , atmospheric correction value PPM and you can also adjust the contrast of the display when the instrument is turned on. The battery operating time will vary depending on the environmental conditions such as ambient temperature, charging time, the number of times of charging and discharging etc.

It is recommended for safety to charge the battery beforehand or to prepare spare full charged batteries. The battery power remaining display shows the power level regarding to the measurement mode now operating.

It may happen that the mode change from the angle mode to the distance mode will stop the operation because of insufficient battery power for the distance mode which consumes more power than angle mode.

To ensure a precise angle measurement, tilt sensors must be turned on. The display can also be used to fine level the instrument. GTSN compensates the vertical angle reading due to inclination of the standing axis in the X direction. When the instrument is out of compensation. To set auto tilt correction from the moment that power is on, see Section 6. The display of Vertical angle is unstable when instrument is on an unstable stage or a windy day.

You can turn off the auto tilt correction function of V angle in this case. In case ON is already selected, the display shows tilt correction value. The setting mode performed here will not be memorized after powering OFF.

The instrument switches to numerical input mode. Example: [1] STU key is pressed twice. HT: 0. Operating procedure. Point the telescope toward the light. Turn the diopter ring and adjust the diopter so that the cross hairs are clearly observed. Turn the diopter ring toward you first and then backward to focus. Aim the target at the peak of the triangle mark of the sighting collimator. Allow a certain space between the sighting collimator and yourself for collimating.

Focus the target with the focusing knob. This adversely affects precision in measurement or survey Eliminate the parallax by carefully focusing and using diopter adjustment. When completed, normal measuring from the required Horizontal angle is possible. Make sure the mode is Horizontal Angle Right measurement. This setting is not memorized after powering off. Make sure the mode is Angle measurement.

Refer to Section Set correction for prism at 0. If the prism is of another manufacture, the appropriate constant shall be set beforehand.

The setting value is kept in the memory even after power is off. Pressing the [ ] key again, the display changes to horizontal HR and vertical V angle and slope distance SD.

The average distance will be displayed. When presetting the number of times as 1, it does not display the average distance, because of single measurement. Single measurement is set at the factory. Make sure the mode displays angle measurement. This setting is not memorized after power off. The unit to be displayed: 0. It is very useful when tailing the moving object or carrying out stake-out work. The unit to be displayed: 10mm Measuring time: approx.

The unit to be displayed: 10mm or 1mm Measuring time: approx. O The difference between the measured distance and the input stake out distance is displayed. Outputting the Measurement Data The results of offset measurement can be output to external device.

Distance measurement mode of the offset measurement Offset measurement will be done by N-time fine measurement mode. Place the prism at the same horizontal distance from the instrument as that of point A0 to measure.

When measuring coordinates of point A0 : Set the instrument height only. Set the prism height to 0. Prism height When sighting to A0, you can select one of two ways. One is to fix vertical angle to the prism position even updown the telescope position, and the other is to gear vertical angle to the updown of telescope movement.

In case following the vertical angle to the movement of telescope, SD Slope Distance and VD Vertical Distance will be changed according to the movement of telescope. Each time pressing the [ ] key, horizontal distance, relative elevation and slope distance are shown in sequence.

Each time pressing [ ] key, N,E and Z coordinate are shown in sequence. To return to the previous mode, press [ESC] key. Forward HD oHD sign. Three random prism points P1, P2, P3 on a plane will be measured at first in the plane offset measurement to determine the measured plane.

Collimate the measuring target point P0 then the instrument calculates and displays coordinate and distance value of cross point between collimation axis and of the plane.

N-time measuring will start. After measuring, the display will show the second point measurement. The instrument calculates and displays coordinate and distance value of cross point between collimation axis and of the plane.

To show coordinate of point P0, press the [ ] key. The display returns to the previous mode. Start measuring over again from the first point. After the measurement, angle measuring display of the right side P3 will be shown. To escape the measuring, press the [ESC] key.

It is possible to retain the coordinates of the occupied point after turning the power off. Prism n,e,z. After entering the values, the display returns coordinate measuring display.

It is possible to retain the height of target after turning the power off. HT Prism height : R. In this mode, special measuring , setting and adjustment are possible. Normal measurement mode [MENU]. HT key. To return to procedure 6, press the [F3] HD key. To return to procedure 8, press the [F2] V key. It is possible to enter the coordinate value directly or calculate from coordinate data file.

MLM mode has two modes. Prism A. Horizontal distance HD between the instrument and prism A will be shown. Horizontal distance HD between the instrument and prism B will be shown. Horizontal distance HD between the instrument and prism C will be shown. HT NEZ ———. Point number input display will be shown. Pressing the [F3] HD key, the display will return to procedure 6. Known point data and coordinate data can use the coordinate data file. Display for Safe UseIn order to encourage the safe use of products and prevent any danger to the operator and othersinstruWe sreadin.

Ignoring or disregard of this display may lead to the danger of death or serious injury. Ignoring or disregard of this display may lead to personal injury or phys-ical damage. Home Documents Topcon gts n total station manual. See Full Reader. Post on Mar views. Category: Documents download. Tags: external battery external power source urisk of fdo chapter battery system drisk of fdo crisk of fdo measuring precision normal performance.

Handling Precautions efore starting work or operation, be sure to check that the instrument is unctioning correctly with normal performance. This reply was deleted. Lcd for topcon Started by joseph Uy in Other. Note: this page contains paid content. Please, subscribe to get an access. Cancel Subscribe.